Firmware & Downloads

RecMicII v1.1.1 (Windows)
2020-01-17
This update fixes a Windows driver installation prompt, upon each new connection to another USB port.
RecMicII v1.1.1 (Mac)
2020-01-17
This update fixes a Windows driver installation prompt, upon each new connection to another USB port.
RecMicII v1.1.1 (BIN)
2018-08-31
This update fixes a Windows driver installation prompt, upon each new connection to another USB port.
RecMic Configuration Tool 1.0.3
2021-06-14
Fixed a bug that an error occurs when trying to set the RecMics with RCT, after starting or closing ODMS when the RCT is active as a resident program. Company name has been changed to 'OM Digital Solutions'.

Technical Specifications

Available models

Models

  • RM‑4010P / RM‑4015P
  • RM‑4100S
  • RM‑4110S

USB functionality

USB Speed

  • USB 2.0 High Speed

USB Classes

  • USB Audio class
  • HID mouse
  • HID vendor (default) / keyboard

Device operation

Main Switch

  • Slide Switch (RM‑4100S, RM‑4110S)
  • Push (RM‑4010P, RM‑4015P)

Programmable button

  • 14 Low noise buttons

Optical trackball

  • Yes, incl. left mouse click function (RM‑4010P, RM4015P, RM‑4110S)

Click lock function for drag & drop

  • Yes (only for models with trackball)

Function buttons

  • 4 (RM‑4100S: 3 additional F‑Buttons)

Acceleration sensor

  • Available

Recording Modes

Recording format

  • PCM (mono, 16bit, 44.1kHz sampling)

Record function

Noise cancellation

  • Variable

Active Directionality

  • Variable

Noise analyzer

  • Available

Pop-filter

  • 3 layers

Operation Modes

Olympus Mode

  • Available (default)

HID Keyboard Modes

  • Custom mode (Customizable button setting to control any third party application (via RCT ‑ RecMic Configuration Tool software)
  • Dragon Mode (Predefined setting for Dragon Speech Recognition)
  • Windows Speech Recognition Mode (Predefined setting for Windows Speech Recognition)

Recording Scenes

  • Quiet environment
  • Noisy environment for Speech Recognition
  • Noisy environment for Classic Dictation

Other Features

Automatic stand detection

  • Available

Automatic microphone mute

  • Yes, when placing on desk

Storage Media

Internal memory

  • No
  • 8GB (RM‑4015P)

Specialized features for medical environment

Chemical resistance

  • Ethanol Isopropanol

Antimicrobial Housing

  • Polygiene®

Compatible Software

Olympus RecMic Configuration Tool (RCT)

  • Version: 1.0 or higher

Third party software

  • Any software which can be controlled via keyboard shortcuts (e.g. Ctrl + H)

Interfaces Input

Microphone type

  • Intelligent 2 microphone system

Frequency response

  • 200 – 9000Hz

Microphone sensitivity / gain

  • ‑ 39dBv

Input Level

  • ‑ 48dBv / + 86dB SPL

Signal-to-noise ratio

  • 59dBA

Microphone characteristics

  • Omni‑directional

Interfaces Output

Speaker

  • 28mm Integrated front loudspeaker

Max. working output

  • 350mW

Power Supply

Standard USB Mode

  • 278mA or less

Low Power USB mode

  • 80mA or less

Dimensions

Cable length

  • 2.5m

Height

  • 171mm

Width

  • 32mm

Depth

  • 43.2mm

Weight

  • 185g including cable
  • 170g (RM‑4100S)
  • 116g without cable (RM‑4010P/RM‑4015P/RM‑4110S)

Exterior

Housing colour

  • Black

Symmetric Housing

  • Suitable for both left and right handed people

Haptics

  • Smooth Surface coating for minimal touch noises (UV coated)

LED

  • 7

Operating Systems & Requirements

Windows

  • Windows 7/8.1/10

System Requirements of Olympus RecMic Configuration Tool (RCT)

Operating system:

  • Microsoft® Windows® 7 • Ultimate/Enterprise/Professional SP1 (x86/x64)
  • Microsoft® Windows® 8.1/10 • Enterprise/Pro (x86/x64)

CPU:

  • 1GHz or higher

Memory:

  • 1 GB or more (x86)/2 GB or more (x64) (Microsoft® Windows® 7/8.1)
  • 2 GB or more (Microsoft® Windows® 10)

Hard disk space:

  • 30 MB or more (A separate space is required to install .NET Framework.)

.NET Framework

  • Version: 4.6

Dragon speech recognition software

  • Dragon Professional/Legal v14 ‑ 15
  • Dragon Medical Practice Edition 2 ‑ 3

Box Contents

RECMIC II ‑ RM‑4100S

  • RM‑4100S
  •  Microphone stand
  •  Quick User Guide (EN/CZ/DK/DE/ES/FI/FR/IT/LIT/NL/PL/RUSV)
  •  Olympus RecMic Configuration Tool (RCT) (to be downloaded from website)

RECMIC II ‑ RM‑4100S PREMIUM KIT

  •  RM‑4110S
  •  ODMS R7 DM Single License
  •  DSS Player for MAC (Software for Macintosh)
  •  Microphone stand
  •  Quick User Guide (EN/CZ/DK/DE/ES/FI/FR/IT/LIT/NL/PL/RUSV)
  •  Olympus RecMic Configuration Tool (RCT) (to be downloaded from website)

Support & Repair

TECHNICAL SUPPORT

Use the link below to open a new support ticket for your product.

REPAIR SERVICE

Use the link below to start a repair service request for your product.

Copyright OM Digital Solutions. All Rights Reserved